Alarm escalation
The watch alarm moves to the backup officer if the watch officer does not respond to the pre-warning or the alarm.
FURUNO · BNWAS
Continuous watch officer monitoring with alarm escalation to backup personnel
IMO-compliant bridge navigational watch alarm system with 4.3" colour LCD that monitors the watch officer and escalates alarms to backup officers.
Price and availability on request. We handle supply, installation and support.
The BR-500 BNWAS monitors the presence of the officer of the watch to help avoid maritime casualties. To confirm alertness, the officer presses a button on the timer reset panel or operates designated navigation equipment such as ECDIS or radar within a preset interval of 3 to 12 minutes. If nothing happens within that time, visual and audible alarms sound in the wheelhouse.
If there is still no response, the alarm passes to cabin panels around the vessel so that backup officers are told of a possible incapacitation and can step in. The system meets IMO MSC.128(75) for BNWAS and MSC.302(87) for Bridge Alert Management, outputs an ALR sentence for the VDR, and offers quick access keys for navigation officer's call and emergency call. The set-up menu is password protected.
The watch alarm moves to the backup officer if the watch officer does not respond to the pre-warning or the alarm.
Meets MSC.128(75) for BNWAS and MSC.302(87) for Bridge Alert Management.
Quick access push keys for navigation officer's call and emergency call.
Manual OFF, Manual ON and AUTO modes, timer interval of 3 to 12 minutes and system test, in a password-protected set-up menu.
Outputs an ALR sentence for the VDR and notifies backup navigators when the optional TCS (Track Control System) has failed.
Alphanumeric and graphic display in English, Japanese, Russian, Chinese and Korean, with optional motion detector and flash beacon.
| Type | Colour LCD |
|---|---|
| Size | 4.3" |
| Resolution | 480 x 272 pixels |
| Temperature (IEC 60945) | Watertight timer reset panel: -25 to +55 °C; other units: -15 to +55 °C |
|---|---|
| Relative humidity | 93% or less at +40 °C |
| Vibration | IEC 60945 Ed. 4 |
| Waterproofing | Watertight timer reset panel: IP56; processor unit: IP22 (bulkhead), IP20 (tabletop); other units: IP22 |
| Input | 100-230 V |
|---|---|
| Consumption | 0.6-0.4 A |
| Type | Bridge navigational watch alarm system |
|---|---|
| Wheelmarked / IMO compliant | Yes |
Specifications are provided by the manufacturer and may change without notice.